EasyManuals Logo

Huawei SmartAX MA5608T User Manual

Huawei SmartAX MA5608T
1979 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #652 background imageLoading...
Page #652 background image
If a native VLAN is configured for the Ethernet port on the ONT, run the display
ont port attribute command in the xPON board mode to check whether the native
VLAN is correct.
2. Check the upstream and downstream ports by checking the MAC address learning
status.
a. Run the display mac-address vlan command to check the MAC address learning
status of the Internet service VLAN.
If the upstream port does not learn a MAC address, check the network
connections between the upstream port and upper-layer devices and check
the configurations of upper-layer devices.
If the downstream port does not learn a MAC address, check whether the
ONT is activated, whether the PC is connected to the right port on the ONT,
and whether the PC is working properly.
b. Run the display ont-learned-mac command to check whether the ONT
connecting to the PON port learned any MAC addresses.
If not, check whether the ONT properly connects to the PC or home gateway
(HGW).
l Verify the voice service using call emulation.
1. Run the ont emulational call command to configure a call emulation test.
huawei(config)#test
huawei(config-test)#ont emulational call caller-port 0/1/0 1 1 telno
77730020
{ <cr>|caller-stop-time<K> }:
Command:
ont emulational call caller-port 0/1/0 1 1 telno 77730020
2. The ONT outputs the call emulation result after the test is complete.
huawei(config-test)#
----------------------------------------------------------------
F/S/P : 0/1/0
ONT-ID : 0
ONT-POTSID : 1
Test type : caller emulational call test
Detected number : 77730020
Reported number : 77730020
Current status : test end
Test Result : success
----------------------------------------------------------------
l Troubleshooting methods for the voice service.
1. Check whether configurations are complete on the OLT.
Run the display ont info command to query the ONT status to check whether the
ONT is registered successfully.
Run the display service-port command to check whether the voice service flow
is configured and whether the inner VLAN ID of the service flow is consistent
with that in the data plan.
2. Check the upstream and downstream ports by checking the MAC address learning
status.
Run the display mac-address vlan command to check the MAC address learning
status of the voice service VLAN.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide
9 FTTH Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
627

Table of Contents

Other manuals for Huawei SmartAX MA5608T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SmartAX MA5608T and is the answer not in the manual?

Huawei SmartAX MA5608T Specifications

General IconGeneral
Dual Power SupplyYes
Humidity5% to 95% (non-condensing)
Uplink Slots2
Maximum GPON Ports16
Input Voltage Range-38.4 V DC to -72 V DC
Device TypeOLT
Power Supply-48 V DC
Operating Temperature-25°C to +55°C
Storage Temperature-40°C to 70°C
Switching Capacity128 Gbps
PortsGPON, XG-PON, 10GE