Item Function Description Commands
direction and PSD
automatic shaping
is used in the
upstream
direction.
l force-friendly-ds-
no-limit-us: force
friendly is used in
the downstream
direction and no
restriction is used
in the upstream
direction.
l block: The
Vectoring legacy
CPE cannot be
activated in
common VDSL2
mode. This mode
is used in
Vectoring mature
phase when its
performance is
concerned and
unnecessary
crosstalk must be
prevented.
Data Plan
The Table 11-16 lists key parameters of vectoring configurations.
Table 11-16 Key parameters of vectoring configurations
Item Data Description
Global vectoring
configurations
enable -
Global band plan
l Band plan type: 998ade
l USO type: type-a
-
Policy for activating a
legacy customer
premises equipment
(CPE)
no-limit The policy for activating a
vectoring legacy CPE is
configured as no-limit at the
initial stage of vectoring
application.
SmartAX MA5600T/MA5603T/MA5608T Multi-service
Access Module
Commissioning and Configuration Guide 11 FTTB and FTTC Solution Configuration
Issue 01 (2014-04-30) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
906