5. Various Functions
5.2 Power-saving function
5-7 ME0342-4B
[2] Setting of Power-saving Method
Select from the following conditions, and set in "stop mode" of the position table, or with
Parameter No. 53Default stop modeusing a numerical value.
Set
value
Operation after positioning complete
Selectable
specifications
0 Servo ON as is All specifications
1
After a fixed time (parameter No. 36 set value) automatic servo OFF
All specifications
2
After a fixed time (parameter No. 37 set value) automatic servo OFF
All specifications
3
After a fixed time (parameter No. 38 set value) automatic servo OFF
All specifications
4 Full servo control
Stepper motor
specification
(Excluding RCP6 Series)
5
After full servo control for a fixed time (parameter No. 36 set
value), automatic servo OFF
Stepper motor
specification
6
After full servo control for a fixed time (parameter No. 37 set
value), automatic servo OFF
Stepper motor
specification
7
After full servo control for a fixed time (parameter No. 38 set
value), automatic servo OFF
Stepper motor
specification
Caution
There is no holding torque during AUTO servo OFF. The actuator will move if external
force is applied. Take extra care when setting.
Do not use AUTO servo OFF when the next travel command is relative specifications
(pitch feed). Misalignment may occur.
Do not use AUTO servo OFF with push-motion operation. The pushing force will be lost.
AUTO servo OFF does not function if operating in teaching mode with a teaching
pendant or the PC software.