Hardware Installations and Upgrades
140 Intel
®
Server Board S2600CP Intel
®
Server System P4000CP Family Service Guide
Comments: This specifies the IP Source for IPv6 addressing for the Intel
®
RMM4
DMN LAN configuration. There is a separate IPv6 Source field for the Baseboard LAN
configuration.
This option is only visible when the IPv6 option is set to Enabled.
When IPv6 addressing is Enabled, the initial value for this field is acquired from the BMC, and
its setting determines whether the other Intel
®
RMM4 DMN LAN IPv6 addressing fields are
display-only (when Dynamic or Auto) or can be edited (when Static).
Back to [BMC LAN Configuration]
16. IPv6 Address
Option Values: [Entry Field 0000.0000.0000.0000.0000.0000.0000.0000,
0000.0000.0000.0000.0000.0000.0000.0000
is default]
Help Text:
View/Edit IPv6 address. Press <Enter> to edit. IPv6 addresses consist of 8 hexadecimal
4 digit numbers separated by colons.
Comments: This specifies the IPv6 Address for the Intel
®
RMM4 DMN LAN. There
is a separate IPv6 Address field for the Baseboard LAN configuration.
This option is only visible when the IPv6 option is set to Enabled.
When IPv6 addressing is used, the initial value for this field is acquired from the BMC. The
setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or
can be edited (when Static).
Back to [BMC LAN Configuration]
17. Gateway IPv6
Option Values: [Entry Field 0000.0000.0000.0000.0000.0000.0000.0000,
0000.0000.0000.0000.0000.0000.0000.0000
is default]
Help Text:
View/Edit Gateway IPv6 address. Press <Enter> to edit. Gateway IPv6 addresses consist
of 8 hexadecimal 4 digit numbers separated by colons.
Comments: This specifies the Gateway IPv6 Address for the Intel
®
RMM4 DMN
LAN. There is a separate Gateway IPv6 Address field for the Baseboard LAN configuration.
This option is only visible when the IPv6 option is set to Enabled.
When IPv6 addressing is used, the initial value for this field is acquired from the BMC. The
setting of IPv6 Source determines whether this field is display-only (when Dynamic or Auto) or
can be edited (when Static).
Back to [BMC LAN Configuration]
18. IPv6 Prefix Length
Option Values: [Entry Field 0 – 128, 64
is default]
Help Text:
View/Edit IPv6 Prefix Length from zero to 128 (default 64). Press <Enter> to edit.