163
INITIAL SETTING 1
This menu appears when the
MEN
U
key and
ENTER
key are pushed simultaneously.
INITIAL SETTING 1
RECEIVER ADJUST
DISPLAY TIMING
GAIN PRESET
COMPARATOR PRESET
STC PRESET
ANTENNA HEIGHT
GPS PRESET
INITIAL SETTING 2
1024
128
128
128
128
UNDER 5
SELECT W/CROSS KEY ( )
PRESS ENT TO SET
PRESS MUNU TO RETURN
BEARING
MBS LEVEL
MBS RANGE
128
128
A
djust the criterion level when
the radar image signal is A/D.
A
djust the maximum sensitivit
y
when the GAIN control is
turned fully to the right (maxi-
mum sensitivity).
Normally, the maximum is set
at 255.
A
djust the distance of the image
on the PPI screen.
A
djust the bearing of the image
on the PPI screen.
Implement various adjustments
on the receiver (including rough
tuning adjustment)
A
djust the strength of the sea
surface clutter suppression.
Select the height to the scanner
unit as follows: 5m or less/ 5 to
10m/ 10m or more.
It optimizes the characteristics
of the sea surface clutter sup-
pression by this setting.
When connected to an external
GPS, set the initial value of the
GPS.
A
djust the strength of the main
bang suppression.
A
djust the range of the main
bang suppression.
INITIAL SETTING 2
SIMULATOR
SELECT W/CROSS KEY ( )
PRESS ENT TO SET
PRESS MUNU TO RETURN
OFF ON
Display the PPI screen for
demonstration purposes.
Display the menu "INITIA
L
SETTING 2".
INITIAL SETTING 2
SET TD NUMBER
Set the time differential receipt
number.
NEXT
NEXT
NEXT