CAUTION: Do not leave the power supply slot empty for a long time while
the switch is on. The power supply must remain in the chassis for proper
airflow.
To remove a power supply from the switch (see Figure 51 on page 194):
1. Place the antistatic bag or the antistatic mat on a flat, stable surface.
2. Disconnect power to the switch by performing one of the following:
AC power supply—If the AC power source outlet has a power switch, set it to the
OFF (0) position. If the AC power source outlet does not have a power switch, gently
pull out the male end of the power cord connected to the power source outlet.
DC power supply—Switch the circuit breaker on the panel board that services the
DC circuit to the OFF position.
3. Remove the power source cable from the power supply faceplate:
AC power supply—Gently pull out the female end of the power cord connected to
the power supply faceplate.
DC power supply—Remove the screws securing the ring lugs attached to the power
source cables to the power supply using the screwdriver, and remove the power
source cables from the power supply. Replace the screws on the terminals and
tighten them.
4. Loosen the locking lever screw on the left front of the power supply by using the
screwdriver.
5. Push down on the locking lever until it is in its lowest position.
6. Grasp the power supply handle and pull firmly to slide it halfway out of the chassis.
7. Place one hand under the power supply to support it and slide it completely out of
the chassis. Take care not to touch power supply components, pins, leads, or solder
connections.
8. Place the power supply in the antistatic bag or on the antistatic mat placed on a flat,
stable surface.
193Copyright © 2016, Juniper Networks, Inc.
Chapter 16: Replacing Power Supply

Table of Contents

Other manuals for Juniper EX3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX3200 and is the answer not in the manual?

Juniper EX3200 Specifications

General IconGeneral
ModelEX3200
Rack Units1U
Layer SupportLayer 2 and Layer 3
Junos OSYes
Maximum VLANs4093
DRAM512 MB
Flash Memory256 MB
Ports24 or 48
Uplink Ports4 SFP
Power SupplyAC or DC
MAC Address Table Size16, 000 entries
Dimensions (W x D x H)17.4 x 14.4 x 1.7 inches
Weight12.3 lb (5.6 kg)
Operating Temperature0°C to 40°C
Operating Humidity10% to 85% (non-condensing)

Related product manuals