for connecting a switch to earth ground. Before you begin connecting a switch to earth
ground, ensure you have the parts and tools required for your switch.
Table 56: Parts and Tools Required for Connecting an EX Series Switch to Earth Ground
Additional
InformationScrewdriver
Screws and
Washers
Grounding Lug
Specifications
Grounding Cable
Requirements
Earthing
Terminal
LocationSwitch
Phillips (+)
number 2
Two 10-32 x .25 in.
screws with #10
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Panduit
LCC10-14BWL or
equivalent—
not provided
14 AWG (2 mm²),
minimum 90°C
wire, or as
permitted by the
local code
Rear panel
of the
chassis
EX2200
Phillips (+)
number 2
Two 10-32 x .25 in.
screws with #10
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Panduit
LCC10-14BWL or
equivalent—
not provided
14 AWG (2 mm²),
minimum 90°C
wire, or as
permitted by the
local code
Rear panel
of the
chassis
EX2300-C
Phillips (+)
number 2
Two 10-32 x .25 in.
screws with #10
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Panduit
LCC10-14BWL or
equivalent—
not provided
14 AWG (2 mm²),
minimum 90°C
wire, or as
permitted by the
local code
Rear panel
of the
chassis
EX2300
See “Special
Instructions
to Follow
Before
Connecting
Earth Ground
to a Switch”
on page 158.
Phillips (+)
number 2
Two 10-32 x .25 in.
screws with #10
split-lock washer—
not provided
Two #10 flat
washers—
not provided
Panduit
LCC10-14BWL or
equivalent—
not provided
14 AWG (2 mm²),
minimum 90°C
wire, or as
permitted by the
local code
Rear panel
of the
chassis
EX3200
Phillips (+)
number 2
Two 10-32 x .25 in.
screws with #10
split-lock washer—
not provided
Two #10 flat
washers—
not provided
Panduit
LCC10-14BWL or
equivalent—
not provided
14 AWG (2 mm²),
minimum 90°C
wire, or as
permitted by the
local code
Rear panel
of the
chassis
EX3300
Phillips (+)
number 2
Two 10-32 x .25 in.
screws with #10
split-lock washer—
not provided
Two #10 flat
washers—not
provided
Panduit
LCC10-14BWL or
equivalent—
not provided
14 AWG (2 mm²),
minimum 90°C
wire, or as
permitted by the
local code
Rear panel
of the
chassis
EX3400
Copyright © 2016, Juniper Networks, Inc.156
EX3200 Switch Hardware Guide

Table of Contents

Other manuals for Juniper EX3200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX3200 and is the answer not in the manual?

Juniper EX3200 Specifications

General IconGeneral
ModelEX3200
Rack Units1U
Layer SupportLayer 2 and Layer 3
Junos OSYes
Maximum VLANs4093
DRAM512 MB
Flash Memory256 MB
Ports24 or 48
Uplink Ports4 SFP
Power SupplyAC or DC
MAC Address Table Size16, 000 entries
Dimensions (W x D x H)17.4 x 14.4 x 1.7 inches
Weight12.3 lb (5.6 kg)
Operating Temperature0°C to 40°C
Operating Humidity10% to 85% (non-condensing)