Table 59: Chassis Component Alarm Conditions on EX3200 Switches
Remedy
Alarm
SeverityAlarm Condition
Chassis
Component
Install a power supply.Minor
(yellow)
A power supply has
been removed from
the chassis.
Power
supplies
Install a power supply recommended by
Juniper Networks.
Minor
(yellow)
An unknown power
supply is installed.
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or call
1-888-314-5822 (toll-free within the United
States and Canada) or 1-408-745-9500
(from outside the United States).
Major
(red)
The power supply is
offline or the power
supply output has
failed.
Install the fan tray.Minor
(yellow)
Fan tray is not
installed.
Fan tray
•
Check the fan.
•
Replace the faulty fan tray.
•
If the above two checks show no
problems, open a support case using the
Case Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Major
(red)
One fan in the
chassis is not
spinning or is
spinning at below
the required speed.
•
Check the fan.
•
Replace the faulty fan tray.
•
If the above two checks show no
problems, open a support case using the
Case Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Major
(red)
Fanfailure–i2c read
failure.