Table 59: Chassis Component Alarm Conditions on EX3200
Switches (continued)
Remedy
Alarm
SeverityAlarm Condition
Chassis
Component
•
Check the fan.
•
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Major
(red)
The temperature
inside the chassis
has exceeded
203° F (95° C).
Temperature
•
Replace the fan tray.
•
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Major
(red)
The temperature
inside the chassis
has exceeded
185° F (85° C) and
a fan has failed.
•
Check the fan.
•
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Minor
(yellow)
The temperature
inside the chassis
has exceeded
176° F (80° C).
•
Replace the fan tray.
•
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or
call 1-888-314-5822 (toll-free within the
United States and Canada) or
1-408-745-9500 (from outside the
United States).
Minor
(yellow)
The temperature
inside the chassis
has exceeded
158° F (70° C) and
a fan has failed.
Open a support case using the Case
Manager link at
http://www.juniper.net/support/ or call
1-888-314-5822 (toll-free within the United
States and Canada) or 1-408-745-9500
(from outside the United States).
Major
(red)
The temperature
sensor has failed.
Copyright © 2016, Juniper Networks, Inc.222
EX3200 Switch Hardware Guide