Unpacking the Switch
Unpacking an EX4200 Switch on page 153
Parts Inventory (Packing List) for an EX4200 Switch on page 154
Registering Products—Mandatory for Validating SLAs on page 156
Unpacking an EX4200 Switch
The EX4200 switch chassis is a rigid sheet-metal structure that houses the hardware
components. EX4200 switches are shipped in a cardboard carton, secured with foam
packing material. The carton also contains an accessory box.
CAUTION: EX4200 switches are maximally protected inside the shipping
carton. Do not unpack the switches until you are ready to begin installation.
To unpack the switch (see Figure 29 on page 154):
1. Move the shipping carton to a staging area as close to the installation site as possible,
but where you have enough room to remove the system components.
2. Position the carton so that the arrows are pointing up.
3. Open the top flaps on the shipping carton.
4. Remove the accessory box and verify the contents in it against the parts inventory on
the label attached to the carton.
5. Pull out the packing material holding the switch in place.
6. Verify the chassis components received against the packing list included with the
switch. An inventory of parts provided with the switch is provided in “Parts Inventory
(Packing List) for an EX4200 Switch” on page 154.
7. Save the shipping carton and packing materials in case you need to move or ship the
switch later.
153Copyright © 2015, Juniper Networks, Inc.

Table of Contents

Other manuals for Juniper EX4200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4200 and is the answer not in the manual?

Juniper EX4200 Specifications

General IconGeneral
ModelEX4200
Switching Capacity128 Gbps
LayerLayer 2 and Layer 3
Form Factor1U
Throughput96 Mpps
Maximum VLANs4096
MAC Address Table Size16, 000
DRAM1 GB
Flash Memory1 GB
Forwarding Rate96 Mpps
JUNOS SoftwareYes
Ports24 or 48
StackingUp to 10 switches in a Virtual Chassis configuration
Power SupplyAC or DC
ManagementCLI, SNMP, J-Web
Input Voltage100-240 VAC or -48 VDC
Operating Temperature0°C to 45°C
RedundancyRedundant power supplies
Virtual Chassis TechnologyYes
Storage Temperature-40°C to 70°C
Humidity5% to 90% non-condensing