5. Ensure that the other holes in the mounting brackets are aligned with the holes in the
side panels. Insert a screw in each hole and tighten the screws.
6. Have one person grasp both sides of the switch, lift the switch, and position it in the
rack, aligning the mounting bracket holes with the threaded holes in the rack or cabinet
rail. Align the bottom hole in both the mounting brackets with a hole in each rack rail,
making sure the chassis is level. See Figure 32 on page 162.
Figure 32: Mounting the Switch on Two Posts in a Rack
g020094
Mounting rack
Mounting bracket
7. Have a second person secure the switch to the rack by using the appropriate screws.
Tighten the screws.
8. Ensure that the switch chassis is level by verifying that all screws on one side of the
rack are aligned with the screws on the other side.
NOTE: If the switch is an EX4200-24F model, we recommend that you insert
dust covers in any unused SFP ports.
Related
Documentation
Connecting Earth Ground to an EX Series Switch on page 171
Connecting AC Power to an EX4200 Switch on page 177
Connecting DC Power to an EX4200 Switch on page 179
Connecting and Configuring an EX Series Switch (CLI Procedure) on page 195
Connecting and Configuring an EX Series Switch (J-Web Procedure) on page 198
Mounting an EX4200 Switch in a Recessed Position in a Rack or Cabinet on page 166
Rack-Mounting and Cabinet-Mounting Warnings on page 280
Copyright © 2015, Juniper Networks, Inc.162
EX4200 Switch Hardware Guide

Table of Contents

Other manuals for Juniper EX4200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4200 and is the answer not in the manual?

Juniper EX4200 Specifications

General IconGeneral
ModelEX4200
Switching Capacity128 Gbps
LayerLayer 2 and Layer 3
Form Factor1U
Throughput96 Mpps
Maximum VLANs4096
MAC Address Table Size16, 000
DRAM1 GB
Flash Memory1 GB
Forwarding Rate96 Mpps
JUNOS SoftwareYes
Ports24 or 48
StackingUp to 10 switches in a Virtual Chassis configuration
Power SupplyAC or DC
ManagementCLI, SNMP, J-Web
Input Voltage100-240 VAC or -48 VDC
Operating Temperature0°C to 45°C
RedundancyRedundant power supplies
Virtual Chassis TechnologyYes
Storage Temperature-40°C to 70°C
Humidity5% to 90% non-condensing

Related product manuals