Ensure that the polarity of the DC input wiring is correct. Under certain conditions,
connections with reversed polarity might trip the primary circuit breaker or damage
the equipment.
For personal safety, connect the green and yellow wire to safety (earth) ground at both
the device and the supply side of the DC wiring.
The marked input voltage of –48 VDC for a DC-powered device is the nominal voltage
associated with the battery circuit, and any higher voltages are only to be associated
with float voltages for the charging function.
Because the device is a positive ground system, you must connect the positive lead to
the terminal labeled RTN, the negative lead to the terminal labeled –48 VDC, and the
earth ground to the device grounding points.
Related
Documentation
General Safety Guidelines and Warnings on page 267
General Electrical Safety Guidelines and Warnings on page 299
DC Power Disconnection Warning on page 308
DC Power Grounding Requirements and Warning on page 309
DC Power Wiring Sequence Warning on page 310
DC Power Wiring Terminations Warning on page 312
Connecting DC Power to an EX2200 Switch
Connecting DC Power to an EX3200 Switch
Connecting DC Power to an EX4200 Switch on page 179
Connecting DC Power to an EX4300 Switch
Connecting DC Power to an EX4500 Switch
Connecting DC Power to an EX4550 Switch
Connecting DC Power to an EX4600 Switch
Connecting DC Power to an EX6200 Switch
Connecting DC Power to an EX8200 Switch
Connecting DC Power to an EX9204 Switch
Connecting DC Power to an EX9208 Switch
Connecting DC Power to an EX9214 Switch
Connecting DC Power to an OCX1100 Switch
Connecting DC Power to an XRE200 External Routing Engine
Connecting DC Power to a QFX3500, QFX3600, or QFX3600-I Device
Connecting DC Power to a QFX5100 Device
307Copyright © 2015, Juniper Networks, Inc.
Chapter 31: Electrical Safety Guidelines and Warnings

Table of Contents

Other manuals for Juniper EX4200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4200 and is the answer not in the manual?

Juniper EX4200 Specifications

General IconGeneral
ModelEX4200
Switching Capacity128 Gbps
LayerLayer 2 and Layer 3
Form Factor1U
Throughput96 Mpps
Maximum VLANs4096
MAC Address Table Size16, 000
DRAM1 GB
Flash Memory1 GB
Forwarding Rate96 Mpps
JUNOS SoftwareYes
Ports24 or 48
StackingUp to 10 switches in a Virtual Chassis configuration
Power SupplyAC or DC
ManagementCLI, SNMP, J-Web
Input Voltage100-240 VAC or -48 VDC
Operating Temperature0°C to 45°C
RedundancyRedundant power supplies
Virtual Chassis TechnologyYes
Storage Temperature-40°C to 70°C
Humidity5% to 90% non-condensing