Table 6: LCD Panel Menu Options (continued)
DescriptionMenu
The Status menu has the following options:
Show VCP status—Choose one of the following:
Press the Enter button to display the Virtual Chassis port (VCP) status: Up, Down, Disabled.
NOTE: This option is available only for an EX4200 switch that is a member of a Virtual Chassis
configuration. It is not available for an EX3200 switch.
Press the Menu button to go to the next option in the Status menu.
Show PSU status—Choose one of the following:
Press the Enter button to display the status of the power supply: OK, Failed, Absent.
Press the Menu button to go to the next option in the Status menu.
Show Environment status—Choose one of the following:
Press the Enter button to display the status of the fan and temperature:
Fan status: OK, Failed, Absent
Temp status: OK, High, Shutdown
Press the Menu button to go to the next option in the Status menu.
Show Junos version—Choose one of the following:
Press the Enter button to display the version of Junos OS for EX Series switches loaded on the switch.
Press the Menu button to go to the next option in the Status menu.
EXIT STAT MENU?—Choose one of the following:
Press the Enter button to exit the Status menu. Then press the Menu button to go to the Maintenance
menu.
On an EX4200 switch that is a member of a Virtual Chassis configuration, press the Menu button to return
to the Show VCP status option.
NOTE: This option is available only for an EX4200 switch that is a member of a Virtual Chassis
configuration. It is not available for an EX3200 switch.
If you do not want users to use Status menu options, disable the entire menu or individual menu options. See
“Configuring the LCD Panel on EX Series Switches (CLI Procedure)” on page 201.
STATUS
Copyright © 2015, Juniper Networks, Inc.16
EX4200 Switch Hardware Guide

Table of Contents

Other manuals for Juniper EX4200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4200 and is the answer not in the manual?

Juniper EX4200 Specifications

General IconGeneral
ModelEX4200
Switching Capacity128 Gbps
LayerLayer 2 and Layer 3
Form Factor1U
Throughput96 Mpps
Maximum VLANs4096
MAC Address Table Size16, 000
DRAM1 GB
Flash Memory1 GB
Forwarding Rate96 Mpps
JUNOS SoftwareYes
Ports24 or 48
StackingUp to 10 switches in a Virtual Chassis configuration
Power SupplyAC or DC
ManagementCLI, SNMP, J-Web
Input Voltage100-240 VAC or -48 VDC
Operating Temperature0°C to 45°C
RedundancyRedundant power supplies
Virtual Chassis TechnologyYes
Storage Temperature-40°C to 70°C
Humidity5% to 90% non-condensing

Related product manuals