EasyManua.ls Logo

Juniper EX4200

Juniper EX4200
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
If you are mounting the switch on a rack or cabinet with other equipment, or if you are
placing it on the desktop or floor near other equipment, ensure that the exhaust from
other equipment does not blow into the intake vents of the chassis.
Leave at least 24 in. (61 cm) both in front of and behind the switch. For service personnel
to remove and install hardware components, you must leave adequate space at the
front and back of the switch. NEBS GR-63 recommends that you allow at least 30 in.
(76.2 cm) in front of the rack or cabinet and 24 in. (61 cm) behind the rack or cabinet.
Related
Documentation
Rack Requirements for EX4200 Switches on page 69
Cabinet Requirements for EX4200 Switches on page 70
General Site Guidelines on page 66
Rack-Mounting and Cabinet-Mounting Warnings on page 280
Cooling System and Airflow in an EX4200 Switch on page 31
73Copyright © 2015, Juniper Networks, Inc.
Chapter 6: Preparation Overview

Table of Contents

Other manuals for Juniper EX4200

Related product manuals