Never install electrical jacks in wet locations unless the jacks are specifically designed
for wet environments.
Operate the device only when it is properly grounded.
Ensure that the separate protective earthing terminal provided on this device is
permanently connected to earth.
Replace fuses only with fuses of the same type and rating.
Do not open or remove chassis covers or sheet-metal parts unless instructions are
provided in the hardware documentation for this device. Such an action could cause
severe electrical shock.
Do not push or force any objects through any opening in the chassis frame. Such an
action could result in electrical shock or fire.
Avoid spilling liquid onto the chassis or onto any device component. Such an action
could cause electrical shock or damage the device.
Avoid touching uninsulated electrical wires or terminals that have not been
disconnected from their power source. Such an action could cause electrical shock.
Always ensure that all modules, power supplies, and cover panels are fully inserted
and that the installation screws are fully tightened.
Related
Documentation
AC Power Electrical Safety Guidelines on page 122
DC Power Electrical Safety Guidelines on page 125
General Electrical Safety Guidelines and Warnings on page 119
Maintenance and Operational Safety Guidelines and Warnings on page 113
Installation Instructions Warning on page 103
Grounded Equipment Warning on page 112
Definitions of Safety Warning Levels
This topic applies to hardware devices in the EX Series product family, which includes
switches, the EX Series Redundant Power System (RPS), and the XRE200 External
Routing Engine.
This topic also applies to hardware devices in the QFX Series.
The documentation uses the following levels of safety warnings (there are two “Warning”
formats):
NOTE: You might find this information helpful in a particular situation, or you
might overlook this important information if it was not highlighted in a Note.
Copyright © 2014, Juniper Networks, Inc.92
EX4600 Switch Hardware Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4600 Series and is the answer not in the manual?

Juniper EX4600 Series Specifications

General IconGeneral
Product SeriesEX4600
10GbE ports24 or 48
CoolingFront-to-back or back-to-front airflow
Rack Units1 U
Virtual ChassisUp to 10 members
MAC address table size288, 000 entries
Memory8 GB DRAM
Layer 3 RoutingYes
AC Power Input100-240V AC
Ports24 or 48 x 10GbE ports
40GbE ports4
100GbE ports0
Power SupplyDual redundant, hot-swappable AC or DC
Jumbo frames9216 bytes
Operating temperature0°C to 45°C
Input voltage100-240 VAC, -40 to -72 VDC
Operating relative humidity5% to 90% noncondensing
FansRedundant
JUNOS OSJunos OS
Storage16 GB flash
DC Power Input-40 to -72 VDC