CAUTION: Before removing or installing components of a device, attach an
electrostatic discharge (ESD) grounding strap to an ESD point and place the
other end of the strap around your barewrist. Failure to use an ESD grounding
strap could result in damage to the switch.
Install the device in compliance with the following local, national, and international
electrical codes:
United States—National Fire Protection Association (NFPA 70), United States
National Electrical Code.
Other countries—International Electromechanical Commission (IEC) 60364, Part 1
through Part 7.
Evaluated to the TN power system.
Canada—Canadian Electrical Code, Part 1, CSA C22.1.
Locate the emergency power-off switch for the room in which you are working so that
if an electrical accident occurs, you can quickly turn off the power.
Make sure that grounding surfaces are cleaned and brought to a bright finish before
grounding connections are made.
Do not work alone if potentially hazardous conditions exist anywhere in your workspace.
Never assume that power is disconnected from a circuit. Always check the circuit before
starting to work.
Carefully look for possible hazards in your work area, such as moist floors, ungrounded
power extension cords, and missing safety grounds.
Operate the device within marked electrical ratings and product usage instructions.
To ensure that the device and peripheral equipment function safely and correctly, use
the cables and connectors specified for the attached peripheral equipment, and make
certain they are in good condition.
You can remove and replace many device components without powering off or
disconnecting powertothe device, as detailed elsewhere in the hardware documentation
for this device. Never install an equipment that it appears to be damaged.
Related
Documentation
General Safety Guidelines and Warnings on page 91
AC Power Electrical Safety Guidelines on page 122
DC Power Electrical Safety Guidelines on page 125
Prevention of Electrostatic Discharge Damage
This topic applies to hardware devices in the EX Series product family, which includes
switches, the EX Series Redundant Power System (RPS), and the XRE200 External
Routing Engine.
Copyright © 2014, Juniper Networks, Inc.120
EX4600 Switch Hardware Guide

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4600 Series and is the answer not in the manual?

Juniper EX4600 Series Specifications

General IconGeneral
Product SeriesEX4600
10GbE ports24 or 48
CoolingFront-to-back or back-to-front airflow
Rack Units1 U
Virtual ChassisUp to 10 members
MAC address table size288, 000 entries
Memory8 GB DRAM
Layer 3 RoutingYes
AC Power Input100-240V AC
Ports24 or 48 x 10GbE ports
40GbE ports4
100GbE ports0
Power SupplyDual redundant, hot-swappable AC or DC
Jumbo frames9216 bytes
Operating temperature0°C to 45°C
Input voltage100-240 VAC, -40 to -72 VDC
Operating relative humidity5% to 90% noncondensing
FansRedundant
JUNOS OSJunos OS
Storage16 GB flash
DC Power Input-40 to -72 VDC