CHAPTER 15
Power and Electrical Safety Information
General Electrical Safety Guidelines and Warnings on page 119
Prevention of Electrostatic Discharge Damage on page 120
AC Power Electrical Safety Guidelines on page 122
AC Power Disconnection Warning on page 124
DC Power Electrical Safety Guidelines on page 125
DC Power Disconnection Warning on page 127
DC Power Grounding Requirements and Warning on page 129
DC Power Wiring Sequence Warning on page 130
DC Power Wiring Terminations Warning on page 131
Multiple Power Supplies Disconnection Warning on page 133
TN Power Warning on page 133
Action to Take After an Electrical Accident on page 134
General Electrical Safety Guidelines and Warnings
This topic applies to hardware devices in the EX Series product family, which includes
switches, the EX Series Redundant Power System (RPS), and the XRE200 External
Routing Engine.
This topic also applies to hardware devices in the QFX Series.
WARNING: Certain ports on the device are designed for use as intrabuilding
(within-the-building) interfaces only (Type 2 or Type 4 ports as described in
GR-1089-CORE) and require isolation from the exposed outside plant (OSP)
cabling. To comply with NEBS requirements and protect against lightning
surges and commercial power disturbances, the intrabuilding ports must not
be metallically connected to interfaces that connect to the OSP or its wiring.
The intrabuilding ports on the device are suitable for connection to
intrabuilding or unexposed wiring or cabling only. The addition of primary
protectors is not sufficient protection for connecting these interfaces
metallically to OSP wiring.
119Copyright © 2014, Juniper Networks, Inc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4600 Series and is the answer not in the manual?

Juniper EX4600 Series Specifications

General IconGeneral
Product SeriesEX4600
10GbE ports24 or 48
CoolingFront-to-back or back-to-front airflow
Rack Units1 U
Virtual ChassisUp to 10 members
MAC address table size288, 000 entries
Memory8 GB DRAM
Layer 3 RoutingYes
AC Power Input100-240V AC
Ports24 or 48 x 10GbE ports
40GbE ports4
100GbE ports0
Power SupplyDual redundant, hot-swappable AC or DC
Jumbo frames9216 bytes
Operating temperature0°C to 45°C
Input voltage100-240 VAC, -40 to -72 VDC
Operating relative humidity5% to 90% noncondensing
FansRedundant
JUNOS OSJunos OS
Storage16 GB flash
DC Power Input-40 to -72 VDC