Table 13: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 3.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operationensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX3200
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 3.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operationensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX3300
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 3.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operationensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX4200
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 3.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operationensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX4300
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 3.
Normal operation ensured in the
temperature range 32° F through
113° F (0° C through 45° C)
Normal operationensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX4500
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 3.
EX4550-32F
switches—Normal operation
ensured in the temperature
range 32° F through 113° F (0°
C through 45° C)
EX4550-32T
switches—Normal operation
is ensured in the temperature
range 32° F through 104° F
(0° C through 40° C)
Normal operationensured in
relative humidity range of
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet (3048
meters)
EX4550
Copyright © 2014, Juniper Networks, Inc.36
EX4600 Switch Hardware Guide
* Optics, Fans and Power supply sold separately for EX4600-40F-S.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4600 Series and is the answer not in the manual?

Juniper EX4600 Series Specifications

General IconGeneral
Product SeriesEX4600
10GbE ports24 or 48
CoolingFront-to-back or back-to-front airflow
Rack Units1 U
Virtual ChassisUp to 10 members
MAC address table size288, 000 entries
Memory8 GB DRAM
Layer 3 RoutingYes
AC Power Input100-240V AC
Ports24 or 48 x 10GbE ports
40GbE ports4
100GbE ports0
Power SupplyDual redundant, hot-swappable AC or DC
Jumbo frames9216 bytes
Operating temperature0°C to 45°C
Input voltage100-240 VAC, -40 to -72 VDC
Operating relative humidity5% to 90% noncondensing
FansRedundant
JUNOS OSJunos OS
Storage16 GB flash
DC Power Input-40 to -72 VDC