3. Use «Up» or «Down» to select the
IP address
line.
4 0 0 m b a r 0 8 : 1 5 A M 8 0 ° C
Header
8.1.1 IP configuration
Menu
IP address 169.254.100.101
active line, factory setting
Subnet mask 255.255.000.000
Gateway 169,254,100.97
DNS Server 1 169,254,100.97
DNS Server 2 169,254,100.97
Restart network
4. Press «Enter».
The first group of numbers of the
IP address
flashes
169.254.100.101
.
5. Use «Up» or «Down» to set the first group of numbers of the
IP address
.
6. Press the «Right» key.
The SECOND group of numbers of the
IP address
flashes
192.168.100.101
.
7. Use «Up» or «Down» to set the second, third and fourth group of numbers of the
IP address
.
The
IP address
is correctly set.
8. Press «Enter».
The setting is applied.
9. Press «Down».
The
Subnet mask
line is displayed.
10. Set the remaining network parameters as described above:
Parameters Setting value Meaning
IP address IP address of the interface X1 Ethernet
Subnet mask Subnet mask of the network
Gateway Gateway address of the network
DNS Server 1 DNS server 1 address
DNS Server 2 DNS server 2 address
Restart network Activate the changed network parameters
Tab. 56 Network parameters
11. Use «Up» or «Down» to select the
Restart network
line.
4 0 0 m b a r 0 8 : 1 5 A M 8 0 ° C
Header
8.1.1 IP configuration
Menu
IP address 192.168.001.010
Example address
Subnet mask 255.255.255.000
Example address
Gateway 192.168.001.001
Example address
DNS Server 1 008.008.008.008
Example address
DNS Server 2 008.008.004.004
Example address
Restart network
Active line
12. Press «Enter».
The check box
Restart network
will flash.
8 Initial Start-up
8.2 Setting the controller
No.: 901700 10 E
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 2.5.3
63

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet