Precondition Access level 2 is activated.
1. Open the 8.1.3
<Communication – Ethernet/SIGMA NETWORK – E-mail>
menu.
2. Use «Up» or «Down» to select the
Repeat cut-off time:
line.
3. Press «Enter».
The set value for
Repeat cut-off time:
in minutes flashes.
4 0 0 m b a r 0 8 : 1 5 A M 8 0 ° C
Header
8.1.3 E-mail
Menu
active:
Activating/deactivating the e-mail function
Blower number: 1
Language: English GB
Setting the language
Repeat cut-off time: 5min
Use SSL:
Encryption option
------------------------------
4. Use «Up» or «Down» to set the value for
Repeat cut-off time:
.
5. Press «Enter».
The setting is applied.
6. Press «Escape» repeatedly to leave this menu.
Result Repeat cut-off time: is set.
8.2.16 Setting the time server
If SIGMA CONTROL 2 is connected to the network, you can set the access to an SNTP server
available in the Internet or a local Intranet. SIGMA CONTROL 2 then automatically imports the
date and time settings and ensures continuous synchronisation of the internal clock with the exter‐
nal time server.
Precondition Access level 2 is activated.
IP configuration is set; see chapter 8.2.14.
The time server's IP address is known. Request the required information from your IT department.
1. Open the 5.1.2
<Configuration – General – Time server>
menu.
2. Use «Up» or «Down» to select the
IP address
line.
4 0 0 m b a r 0 8 : 1 5 A M 8 0 ° C
Header
5.1.2 Time server
Menu
active:
Activating/deactivating the time server function
IP address 192.053.103.103
Example address, time server
3. Press «Enter».
The first group of numbers of the
IP address
flashes
192.053.103.103
.
4. Use «Up» or «Down» to set the first group of numbers of the
IP address
.
8 Initial Start-up
8.2 Setting the controller
66
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 2.5.3 No.: 901700 10 E

Table of Contents

Other manuals for KAESER SIGMA CONTROL 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the KAESER SIGMA CONTROL 2 and is the answer not in the manual?

KAESER SIGMA CONTROL 2 Specifications

General IconGeneral
Controller TypeMicroprocessor-based
ModelSIGMA CONTROL 2
ManufacturerKAESER
Input Voltage24 V DC
Protection ClassIP54
Communication ProtocolsModbus, Profibus
Data LoggingComprehensive data logging
Remote MonitoringYes
Communication InterfaceEthernet