Activating/deactivating the "Automatic restart" function
Precondition Access level 2 is activated.
1. Open the 5.3
<Configuration ā Restart>
menu.
2. Use «Up» or «Down» to select the
Automatic restart
line.
4 0 0 m b a r 0 8 : 1 5 A M 8 0 ° C
Header
5.3 Restart
Menu
Automatic restart ā
Automatic restart is deactivated
Delay 10 s
Set/expiring delay time
3. Press «Enter».
The setting mode is active.
4. Press the «Up» key.
The check box is activated.
4 0 0 m b a r 0 8 : 1 5 A M 8 0 ° C
Header
5.3 Restart
Menu
Automatic restart ā
Active line with deactivated check box
Delay 10 s
Set/expiring delay time
5. Press the «Enter» key.
The setting is applied.
Result The "Automatic restart" function is activated.
8.5.4 Controlling machine from a remote location
If the machine is to be started and stopped from a remote control centre, provide the following setā
tings:
Overview
ā Setting the load signal to remote mode
ā Setting the idle signal to remote mode
ā If necessary, activate the Ā«Time controlĀ» key and configure the clock program (see chapā
ter 8.5.1.2).
ā Activating the remote control
ā Press the Ā«ON Ā»key. The
On
LED lights green.
Two methods are available to start the machine remotely from a control centre: