OPERATION DETAILED CONTROLS AND GAUGES
3-143
q When removing the nozzle at tip of the grease gun from the
grease fitting, carefully angle the tip of nozzle slightly and
remove it.
q When there is only a small amount of grease left in the
grease can, the pump will not pump out grease, so move
the grease to the center or fill the can with new grease.
Supplying Grease
When replacing grease can
When replacing the grease can, do as follows.
1. Open storage case cover (4) of grease can (2) at 2 places.
2. Remove quick couplers (5), (6), (7), wiring harness (8), wir-
ing clamp (9) and mounting bolts (10).