6. COOLING SYSTEM
6-7
MXU 500
Place the machine on a flat, level surface.
Fill the reserve tank to the upper level
(FULL) line.
Fill the system with the recommended
coolant through the filler opening up to the
filler neck.
Bleed air from the system as follow:
1. Start the engine and let it idle for 23
minutes.
2. Snap the throttle three to four times to
bleed air from the system.
3. Stop the engine and add coolant to the
proper level if necessary. Reinstall the
radiator cap.
4. Check the level of coolant in the reserve
tank and fill to the upper level if it is
low.
Reserve Tank Cap
Filler Neck