240 X75HD/X75SD Installation and Operation Manual
Appendix B: Troubleshooting
Alarms
Major and Minor Alarms are on
Problem
When the unit is powered up, all or many of the Alarm LEDs and
network alarms are activated.
Solution 1
The X75 monitors all video and audio inputs, fans, and power supplies.
When it detects failure conditions, it activates alarms because the
factory default is set to monitor all alarms. You can globally disable all
of the alarms, or manually enable only those that you want to monitor.
To globally disable all of the alarms in the X75HD/X75SD control
panel and in the Web browser, follow this path:
System Config>Alarm Assert Setup>Enable All Alarms and then
select Disable.
Solution 2
You can choose to disable specific alarms, while leaving others
activated.
To configure and activate only the alarms that you wish to monitor,
using the X75HD/X75SD control panel, follow these steps:
1. Press the Option button and then select the Configure Alarm
menu.
2. Select the desired alarm parameter by pressing the Enter button.
3. Within this parameter menu, configure the alarm appropriately.
To configure and activate only the alarms that you wish to monitor,
using the Web Browser, follow these steps:
1. Open up your Internet browser.
2. Type the IP Address of the X75 frame on the Address field (see
Figure B-8).