Display code Short designaon Default seng Seng range Address Category
P108.02 Apparent power x.xxx kVA - (Read only) 0x2DA2:002 general
P109.xx Output energy
P109.01 Motor x.xx kWh - (Read only) 0x2DA3:001 general
P109.02 Generator x.xx kWh - (Read only) 0x2DA3:002 general
P110.xx AI1 diagnoscs
P110.01 AI1 terminal % x.x % - (Read only) 0x2DA4:001 general
P110.02 AI1 scaled freq. x.x Hz - (Read only) 0x2DA4:002 general
P110.03 AI1 scaled PID x.xx PID unit - (Read only) 0x2DA4:003 general
P110.04 AI1 scaled torq. x.x % - (Read only) 0x2DA4:004 general
P110.16 AI1 status - - (Read only) 0x2DA4:016 general
P111.xx AI2 diagnoscs
P111.01 AI2 terminal % x.x % - (Read only) 0x2DA5:001 general
P111.02 AI2 scaled freq. x.x Hz - (Read only) 0x2DA5:002 general
P111.03 AI2 scaled PID x.xx PID unit - (Read only) 0x2DA5:003 general
P111.04 AI2 scaled torq. x.x % - (Read only) 0x2DA5:004 general
P111.16 AI2 status - - (Read only) 0x2DA5:016 general
P112.xx AO1 diagnoscs
P112.01 AO1 Voltage x.xx V - (Read only) 0x2DAA:001 general
P112.02 AO1 Current x.xx mA - (Read only) 0x2DAA:002 general
P116.00 Actual sw. freq. - - (Read only) 0x293A general
P117.xx Heatsink temp.
P117.01 Heatsink temp. x.x °C - (Read only) 0x2D84:001 general
P118.00 Digital inputs - - (Read only) 0x60FD general
P119.00 Keypad status - - (Read only) 0x2DAC general
P120.00 Int. HW states - - (Read only) 0x2DAD general
P121.01 PID setpoint x.xx PID unit - (Read only) 0x401F:001 general
P121.02 PID process var. x.xx PID unit - (Read only) 0x401F:002 general
P121.03 PID status - - (Read only) 0x401F:003 general
P123.00 Mot. i2t ulis. x % - (Read only) 0x2D4F general
P125.xx Inverter diag.
P125.01 Acve control - - (Read only) 0x282B:001 general
P125.02 Acve setpoint - - (Read only) 0x282B:002 general
P125.03 Keypad LCD stat. - - (Read only) 0x282B:003 general
P125.04 Drive mode - - (Read only) 0x282B:004 general
P126.xx Status words
P126.01 Cause of disable - - (Read only) 0x282A:001 general
P126.02 Cause of QSP - - (Read only) 0x282A:002 general
P126.03 Cause of stop - - (Read only) 0x282A:003 general
P126.05 Device status - - (Read only) 0x282A:005 general
P135.xx Device ulisat.
P135.04 ixt ulisaon x % - (Read only) 0x2D40:004 general
P135.05 Error response Fault [3] Selecon list 0x2D40:005 general
P140.xx Sequencer diag
P140.01 Acve Step - - (Read only) 0x2DAE:001 Sequencer
P140.02 StepTime elapsed x.x s - (Read only) 0x2DAE:002 Sequencer
P140.03 StepTime remain x.x s - (Read only) 0x2DAE:003 Sequencer
P140.04 Steps complete - - (Read only) 0x2DAE:004 Sequencer
P140.05 Steps remain - - (Read only) 0x2DAE:005 Sequencer
P140.06 Acve sequence - - (Read only) 0x2DAE:006 Sequencer
P140.07 Acve segment - - (Read only) 0x2DAE:007 Sequencer
P140.08 SeqTime remain % x % - (Read only) 0x2DAE:008 Sequencer
P140.09 SeqTime remain x.x s - (Read only) 0x2DAE:009 Sequencer
P150.00 Error code - - (Read only) 0x603F general
P151.xx Life-diagnosis
* Default seng dependent on the model.