EasyManua.ls Logo

Lenze i410 - Page 255

Lenze i410
334 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Display code Short designaon Default seng Seng range Address Category
P208.07 OU reset thresh. x V - (Read only) 0x2540:007 general
P210.00 Min. frequency 0.0 Hz 0.0 ... 599.0 Hz 0x2915 general
P211.00 Max. frequency Device for 50-Hz mains:
50.0 Hz De
vice for 60-Hz
mains: 60.0 Hz
0.0 ... 599.0 Hz 0x2916 general
P220.00 Accelerat.me 1 5.0 s 0.0 ... 3600.0 s 0x2917 general
P221.00 Decelerat.me 1 5.0 s 0.0 ... 3600.0 s 0x2918 general
P222.00 Accelerat.me 2 5.0 s 0.0 ... 3600.0 s 0x2919 general
P223.00 Decelerat.me 2 5.0 s 0.0 ... 3600.0 s 0x291A general
P224.00 Ramp 2 thresh. 0.0 Hz 0.0 ... 599.0 Hz 0x291B general
P225.00 QSP dec. me 1.0 s 0.0 ... 3600.0 s 0x291C general
P226.03 Stop threshold 10.0 % 0.0 ... 100.0 % 0x291E:003 general
P230.xx Opcal tracking
P230.01 Start detecon Stop [0] Selecon list 0x2021:001 general
P230.02 Blink. duraon 5 s 0 ... 3600 s 0x2021:002 general
P300.00 Motor ctrl mode VFC open loop [6] Selecon list 0x2C00 general
P301.00 Modes of op. MS: Velocitymode [-2] Selecon list 0x6060 general
P302.00 V/f charac.shape Linear [0] Selecon list 0x2B00 general
P303.xx V/f shape data
P303.01 Base voltage 230 V * 0 ... 5000 V 0x2B01:001 MCTRL
P303.02 Base frequency Device for 50-Hz mains: 50 Hz
* Device for 60-Hz mains:
60 Hz *
0 ... 1500 Hz 0x2B01:002 MCTRL
P304.00 Limit. rotaon Both rot. direct [1] Selecon list 0x283A general
P305.00 Switching freq. 0 * 1 ... 33 0x2939 general
P308.xx Motor overload
P308.01 Max.load.for 60s 150 % 30 ... 200 % 0x2D4B:001 general
P308.02 Speed comp. On [0] Selecon list 0x2D4B:002 general
P308.03 Response Fault [3] Selecon list 0x2D4B:003 general
P310.xx Mot.phase.fail.
P310.01 Response No response [0] Selecon list 0x2D45:001 general
P310.02 Current thresh. 5.0 % 1.0 ... 25.0 % 0x2D45:002 general
P310.03 Voltage thresh. 10.0 V 0.0 ... 100.0 V 0x2D45:003 general
P315.xx Slip compens.
P315.01 Slip: gain 100.00 % -200.00 ... 200.00 % 0x2B09:001 general
P315.02 Filter me 100 ms 1 ... 6000 ms 0x2B09:002 general
P316.xx V/f boosts
P316.01 Fixed V/f boost 2.5 % * 0.0 ... 20.0 % 0x2B12:001 MCTRL
P316.02 Dynam. V/f boost 0.0 % 0.0 ... 20.0 % 0x2B12:002 general
P317.xx Skip frequencies
P317.01 Skip frequency 1 0.0 Hz 0.0 ... 599.0 Hz 0x291F:001 general
P317.02 Skip bandwidth 1 0.0 Hz 0.0 ... 10.0 Hz 0x291F:002 general
P317.03 Skip frequency 2 0.0 Hz 0.0 ... 599.0 Hz 0x291F:003 general
P317.04 Skip bandwidth 2 0.0 Hz 0.0 ... 10.0 Hz 0x291F:004 general
P317.05 Skip frequency 3 0.0 Hz 0.0 ... 599.0 Hz 0x291F:005 general
P317.06 Skip bandwidth 3 0.0 Hz 0.0 ... 10.0 Hz 0x291F:006 general
P318.xx Oscillat. damp.
P318.01 Gain 150 % -400 ... 400 % 0x2B0A:001 MCTRL
P318.02 Filter me 30 ms 1 ... 600 ms 0x2B0A:002 MCTRL
P319.00 Field weak thold 0.0 Hz -599.0 ... 599.0 Hz 0x2B0C general
P320.xx Motor parameters
P320.04 Rated speed Device for 50-Hz mains:
1450
rpm Device for 60-Hz
mains: 1750 rpm
50 ... 50000 rpm 0x2C01:004 MCTRL
* Default seng dependent on the model.
Using accessories
K
eypad
Keypad parameterisaon mode
255

Table of Contents

Other manuals for Lenze i410