EasyManua.ls Logo

LSIS LSLV-S100 - Under Load Fault Trip and Warning

LSIS LSLV-S100
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of Functions
263
Code
Comm.
Address
Name
LCD Display
Setting Range
Initial
value
Property*
V/F
SL
Ref.
30.00~180.00(
Hz)
[PM Sensorless]
19
0h1113
Start
frequency
Start Freq
0.01-10.00(Hz)
0.50
X/A
O
I/P
p.95
20
0h1114
Maximum
frequency
Max Freq
40.00~400.00(
Hz)
[V/F, Slip
Compen]
40.00~120.00(
Hz)
[IM Sensorless]
40.00~180.00(
Hz)
[PM Sensorless]
60.00
X/A
O
I/P
p.105
21
0h1115
Select speed
unit
Hz/Rpm Sel
0
Hz Display
0:Hz
Display
O/L
O
I/P
p.77
1
Rpm
Display
22
4
0h1116 (+)Torque gain (+)Trq Gain
50.0 ~ 150.0[%]
100.0 O/A X I -
23
4
0h1117 (-)Torque gain (-)Trq Gain 50.0 ~ 150.0[%] 100.0 O/A X I -
24
4
0h1118
(-)Torque gain
0
(-)Trq Gain0 50.0 ~ 150.0[%] 80.0 O/A X I -
25
4
0h1119
(-)Torque
offset
(-)Trq Offset 0.0 ~ 100.0[%] 40.0 O/A X I -
80
5
0h1150
Select ranges
at power input
-
Select ranges
inverter
displays at
power input
0: run
frequency
O/7
O
I/P
-
0
Run
frequency
1
Acceleratio
n time
2
Decelerati
on time
3
Command
source
4
Frequency
reference
source
5
Multi-step
speed
4
Displayed when dr.10 is set to 1 (YES)
5
Will not be displayed when an LCD keypad is in use

Table of Contents

Other manuals for LSIS LSLV-S100