268
Table of Functions
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property*
V/F SL Ref.
2
ALL (Static
type)
3
Rs+Lsigma
(Rotation
type)
6
Tr (Static
type)
7
All PM
21 -
Stator
resistance
Rs
Dependent on
motor setting
Depen
dent
on
motor
setting
X/A X I/P p.144
22 -
Leakage
inductance
Lsigma X/A X I p.144
23 -
Stator
inductance
Ls X/A X I
p.144
24
7
-
Rotor time
constant
Tr
25-5000(ms) - X/A X I p.144
25
7
-
Stator
inductance
scale
Ls Scale
50 ~ 150[%] 100 X/A X I
-
26
7
-
Rotor time
constant scale
Tr Scale
50 ~ 150[%] 100 X/A X I
-
28
8
-
D-axis
inductance
Ld (PM)
Settings vary
depending on
the motor
specifications.
0 X/A X P
29
8
Q-axis
inductance
Lq (PM)
0 X/A X P
30
8
Flux reference PM Flux Ref
0.147 X/A X P
31
7
Regeneration
inductance
scale
Ls Regen
Scale
70 ~ 100[%] 80 X/A X I
-
32
8
-
Q-axis
inductance
scale
Lq(PM) Scale 50150[%] 100 X/A X P
34
8
-
PM auto tuning
level
Ld,Lq Tune
Lev
20.050.0[%] 33.3 X/A X P
35
8
-
PM auto tuning
frequency
Ld,Lq Tune Hz 80.0150.0[%] 100.0 X/A X P
41
9
0h1229
User
frequency1
User Freq 1
0.00-Maximum
frequency(Hz)
15.00 X/A O X p.97
7
Displayed when dr.09 is set to 4(IM Sensorless)
8
Displayed when dr.09 (Control Mode) is set to 6 (PM Sensorless).
9
Displayed if either bA.07 or M2.25 is set to 2 (User V/F).