Code
Name LCD Display Setting Range
V/F SL Ref.
11 0h140B
Continued
operation
duration
Hold Time 0.00-60.00(s) 0.00 X/A X I p.150
12
31
0h140
D
controller
proportional
gain1
ASR P Gain
1
0~5000 100 X/A X P
13
31
0h140F
PM S/L speed
controller integral
gain1
ASR P Gain
1
0~5000 150 X/A X P
15
31
0h1410
controller
proportional
gain2
ASR P Gain
1
0~5000 100 X/A X P
16
31
0h1410
controller integral
gain2
ASR P Gain
1
0~9999 150 X/A x P
20
30
0h1414
gain display
SL2 G View
Sel
0:No O/A X I p.150
1 Yes
21
30
0h1415
controller
proportional
ASR-SL
P Gain1
0-5000(%)
Depen
dent on
motor
setting
O/A X I p.150
22
30
0h1416
controller integral
ASR-SL I
Gain1
10-9999(ms) O/A X I p.150
23
32
0h1417
controller
proportional
ASR-SL P
Gain2
1.0-1000.0(%) O/A X I p.150
24
32
0h1418
controller integral
ASR-SL I
Gain2
1.0-1000.0(%) O/A X I p.150
25
32
0h1419
controller integral
ASR-SL I
Gain0
10~9999(ms) O/A X I -
31
Displayed when dr.09 (Control Mode) is set to 6 (PM Sensorless).
32
Displayed when dr.09 is set to 4 (IM Sensorless) and Cn.20 is set to 1 (YES).