Table of Functions
291
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property*
V/F SL Ref.
Off delay
52 0h1634
Multi-
function
output
contact
selection
DO
NC/NO Sel
Q1, Relay1
00
52
X/A O
I/P
p.202
0
A contact (NO)
1 B contact (NC)
53 0h1635
Fault output
On delay
TripOut
OnDly
0.00-100.00(s) 0.00 O/A O I/P
p.201
54 0h1636
Fault output
Off delay
TripOut
OffDly
0.00-100.00(s) 0.00 O/A O I/P
p.201
55 h1637
Timer
On delay
TimerOn
Delay
0.00-100.00(s) 0.00 O/A O I/P
p.188
56 0h1638
Timer
Off delay
TimerOff
Delay
0.00-100.00(s) 0.00 O/A O I/P
p.188
57 0h1639
Detected
frequency
FDT
Frequency
0.00-Maximum
frequency(Hz)
30.00 O/A O I/P
p.197
58 0h163A
Detected
frequency
band
FDT Band
0.00-Maximum
frequency(Hz)
10.00 O/A O
I/P
p.197
61 0h163D
Pulse output
gain
TO Mode
0
Frequency
0:
Frequen
cy
O/A O
I/P
p.195
1
Output Current
2
Output Voltage
3
DCLink Voltage
4
Torque
5
Output Power
6
Idse
7
Iqse
8
Target Freq
9
Ramp Freq
10
Speed Fdb
12
PID Ref Value
13
PID Fdb Value
14
PID Output
15
Constant
62 0h163E
Pulse output
gain
TO Gain -1000.0-1000.0(%) 100.0 O/A O I/P
p.195
63 0h163F
Pulse output
bias
TO Bias -100.0-100.0(%) 0.0 O/A O I/P
p.195
64 0h1640
Pulse output
filter
TO Filter 0-10000(ms) 5 O/A O I/P
p.195
52
The initial value 0000 will be displayed on the keypad as .