2 Push and hold the levers on both sides of the cable guide (❶) and then remove the cable
guide by pulling it directly away from the front of the inverter (❷). In some models where the
cable guide is secured by a bolt, remove the bolt first.
3 Push and hold the tab on the right side of the control terminal cover. Then remove the cover
by lifting it from the bottom and moving it away from the front of the inverter.
4 Connect the cables to the power terminals and the control terminals. For cable specifications,