71
Learning Basic Features
[Bipolar input voltage and output frequency]
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Operation Frq
Frequency reference
source
Freq Ref Src 2 V1 012 -
In
01
Frequency at
maximum analog
input
Freq at 100% 60.00
0Max
Frequency
Hz
05
V1 input monitor
V1 Monitor
0.00
0.0012.00V
V
06
V1 polarity options
V1 Polarity
1
Bipolar
0–1
-
12
V1 minimum input
voltage
V1- volt x1 0.00 10.000.00V V
13
V1 output at
minimum voltage (%)
V1- Perc y1 0.00 -100.000.00% %
14
V1maximum input
voltage
V1- Volt x2 -10.00 -12.00 0.00V V
15
V1 output at
maximum voltage (%)
V1- Perc y2 -100.00 -100.000.00% %
Rotational Directions for Different Voltage Inputs
Command / Voltage
Input
Input voltage
0
10V -10
0V
FWD
Forward
Reverse
REV
Reverse
Forward