72
Learning Basic Features
-1010V Voltage Input Setting Details
Code
Description
In.12 V1- volt x1
In.15 V1- Perc y2
Sets the gradient level and off-set value of the output frequency in relation to the
input voltage. These codes are displayed only when In.06 is set to 1 (bipolar).
As an example, if the minimum input voltage (at V1) is set to -2 (V) with 10%
output ratio, and the maximum voltage is set to -8 (V) with 80% output ratio
respectively, the output frequency will vary within the range of 6 - 48 Hz.
[In.12 V1-volt X1In.15 V1 Perc y]
For details about the 0+10V analog inputs, refer to the code descriptions In.08
V1 volt x1In.11 V1 Perc y2 on page 69.
4.1.3.3 Setting a Reference Frequency using Input Current (I2)
You can set and modify a frequency reference using input current at the I2 terminal after selecting
current input at SW 2. Set the Frq (Frequency reference source) code in the Operation group to 5
(I2) and apply 420mA input current to I2.
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Operation
Frq
Frequency reference
source
Freq Ref Src 5 I2
012
-
In
01
Frequency at
maximum analog input
Freq at 100% 60.00
0
Maximum
Frequency
Hz
50
I2 input monitor
I2 Monitor 0.00
0.0024.00
mA
52
I2 input filter time
constant
I2 Filter 10
010000
ms
53
I2 minimum input
current
I2 Curr x1 4.00 0.0020.00 mA