4. Parameters
4-49
Parameter Unit Initial
Details
Code Name Minimum
Maximu
m
Cn-14
Absolute encoder reset - -
Resets the absolute encoder.
(Details: Refer to "5.2 Handling.")
Abs encoder reset - -
Cn-15
Max load clear - -
Reset the instantaneous maximum load factor to
0.
[UP]: Displays the + forward maximum load
factor.
[DOWN]: Displays the - direction maximum
load factor.
[SET]: Initializes the maximum load factor.
(Details: Refer to "5.2 Handling.")
Max load clear - -
Cn-16
Parameter lock - -
Lock or Unlock whole parameter.
[UP] : Unlock
[DOWN] : Lock
(Details: Refer to “5.2 Handling.”)
Parameter lock - -
Cn-17
Current offset - -
Store existing current offset value into [P0-27]
~[P0-28] Parameter.
(Details: Refer to “5.2 Handling.”)
Calculate current offset - -