5. Handling and Operation
5-15
5.2.10 Parameter Reset [Cn-09]
Reset parameter data.
[Example of initializing parameters]
Order Loader Displays Keys to Use What to Do
1
Displays the speed control mode with
main power and control power
permitted.
Press [MODE] to move to [Cn-00].
2
Press [UP] or [DOWN] to move to
[Cn-09].
3
Press [SET] to enter parameter reset.
4
Press [SET] to reset data.
[done] is displayed.
5
Press [MODE] for a second to return
to [Cn-09].
[Cn-09 In the case of parameter initialization, unapplied parameters]
Parameter
Detailed parameter
P0-XX P0-00~P0-02, P0-04, P0-05, P0-10, P0-11, P0-27~P0-29
P2-XX P2-00~P2-10, P2-17, P2-18, P2-20, P2-21
” indicates flickering.