MERLIN LEGEND Communications System Release 6.1
Feature Reference
555-661-110
Issue 1
August 1998
Applications
Page I-46Integrated Solution II
I
Feature Interactions 65
Account Code Entry CAS IS II associates account codes entered by users before or during
calls with accounts and individuals; they appear on CAS IS II reports.
Coverage An inside call on a VMI port that transfers to an inside extension does not
go to coverage. It continues to ring at the inside extension.
If a sender programs the telephone so that only outside calls are sent to
coverage, calls received on ICOM or SA buttons are not sent to voice
mail.
In Release 2.0 and later, outside calls that would normally proceed to
AUDIX Voice Power as coverage calls do not do so if the telephone that
sends the call to Group Coverage has activated Coverage VMS Off. No
special action is needed in AUDIX Voice Power programming to activate
this feature.
Group Calling With integrated VMI ports in AUDIX Voice Power, mode codes identify
coverage calls that overflow from one calling group to another calling
group. As a result, the overflow calling group’s number appears in the
Called Party field of the mode code.
Leave Message If a Leave Message notification is left in a mailbox in a system with heavy
VMI traffic, the user may have to dial out manually for messages.
In Release 2.0 and later, when AUDIX Voice Power sends a Leave
Message notification to an extension, the system identifies the voice mail
system as the sender of the message. As a result, when the voice mail
subscriber uses the Return Call feature, the call goes to any available
voice mail port, not just to the specific port that generated the message.
This improves access by reducing the chance of getting a busy port.
Night Service If the AVP Automated Attendant handles only after-hours calls, a phantom
extension (an unused extension or vacant port) must be programmed as
a member of a Night Service group associated with the system operator.
In turn, this phantom extension is covered by a calling group with
integrated VMI ports as members. If an incoming call is not answered in
the programmed number of rings, the control unit sends the call to the
calling group with the VMI ports. Because of prior programming, AVP
recognizes the call to be from the phantom extension and provides
Automated Attendant service rather than the usual Call Answer service.
SMDR CAS IS II uses the call information provided by the system’s built-in
SMDR feature to process calls. There are two system formats for SMDR:
Basic and ISDN.

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals