Section 5 – TROUBLESHOOTING Mini-Crawler Crane M A E D A
5-92 1/2019 MC405C-3
Main cause
―――
The Transmitter defective
• The Accelerator lever was
pulled, when power was
turned ON.
• Return the
Accelerator lever and
push the Reset
*Maintenance/replace
―――
The Receiver PCB defective
• Data error in the memory.
• Power on the
*Maintenance/replace
―――
The Receiver PCB defective
• CPU error
• Power on the
*Maintenance/replace
―――
The Transmitter, internal
devices defective.
• Operation levers were not in
the neutral position, when
• Return operation
levers and push the
*Maintenance/replace
――― ―――
The Transmitter, internal
Devices defective.
• Data error in the memory.
• Power on the
*Maintenance/replace
―――
Breaking of wire for telescopic
control
―――
Breaking of wire for hoisting
control
―――
Breaking of wire for derricking
control
*Maintenance/replace
―――
Breaking of wire for slewing
control
―――
Breaking of wire for accelerator
―――
The Crane operates perfectly
under the manual mode but
some functions are not
available in the remote control
mode.
• The Receiver PCB defective.
• Wiring failure between the
Receiver PCB and the control
valve solenoids.
• Electromagnetic proportional
control reducing valve error.
*Maintenance/replace
*Maintenance/replace