Section 5 – TROUBLESHOOTING Mini-Crawler Crane M A E D A
5-92 1/2019 MC405C-3
Error display
Main cause
Remedy
Transmitter
Receiver
Remedy 1
Remedy 2
―――
The Transmitter defective
The Accelerator lever was
pulled, when power was
turned ON.
Return the
Accelerator lever and
push the Reset
button.
*Maintenance/replace
―――
The Receiver PCB defective
Data error in the memory.
Power on the
Receiver, again.
*Maintenance/replace
―――
The Receiver PCB defective
CPU error
Power on the
Receiver, again.
*Maintenance/replace
―――
The Transmitter, internal
devices defective.
Operation levers were not in
the neutral position, when
power was turned ON.
Return operation
levers and push the
Reset button.
*Maintenance/replace
――― ―――
The Transmitter, internal
Devices defective.
Data error in the memory.
Power on the
Transmitter, again.
*Maintenance/replace
―――
Breaking of wire for telescopic
control
*Maintenance/replace
―――
Breaking of wire for hoisting
control
*Maintenance/replace
―――
Breaking of wire for derricking
control
*Maintenance/replace
―――
Breaking of wire for slewing
control
*Maintenance/replace
―――
Breaking of wire for accelerator
*Maintenance/replace
―――
Valve neutral error
*Maintenance/replace
The Crane operates perfectly
under the manual mode but
some functions are not
available in the remote control
mode.
The Receiver PCB defective.
Wiring failure between the
Receiver PCB and the control
valve solenoids.
Electromagnetic proportional
control reducing valve error.
*Maintenance/replace
*Maintenance/replace
*Maintenance/replace

Table of Contents

Other manuals for Maeda MC405C-3

Related product manuals