272
3. Remove the 2 attachment bolts (6) and remove the
driver seat floor cover (7).
4. Remove all the battery caps (8) (6 caps) and refill
distilled water up to the maximum level (1).
NOTES
If electrolyte is spilled, pour diluted sulfuric acid.
5. Check the breather hole of the battery cap (8) and clean
if it is clogged before tightening the cap securely.
6. After refilling the battery electrolyte, close the driver
seat floor cover (7), set the 2 attachment bolts (6) and
battery cover (3) back into their original positions, and
securely tighten the 4 attachment bolts (4).
[10] CHECKING HORN FOR OPERATION
1. Turn “ON” the starter switch and conduct the following
inspection.
2. Press the horn switch to verify that the horn sounds.
If not, the horn may be faulty or the circuit may be open.
Ask us or our sales service agency for repair.
[11] CHECKING HEADLIGHTS FOR OPERATION
1. Turn “ON” the starter switch and conduct the following
inspection.
2. Press the light switch and check that the indicator of
monitor and the headlight on the front of the machine
turns on.
If it does not, a blown bulb or wiring failure is likely.
Contact us or our sales service agency for repair.