2250 SERVICE/MAINTENANCE MANUAL ELECTRIC SYSTEM
3
E-27 Not Used I/O 4 (DI)
E-28 Not Used I/O 4 (DI)
E-29 82MD Boom Hoist Motor Control
0.98 volts to 8.01 volts: 0% to 100%
Motor Command
I/O 3 (AO)
E-30 Not Used I/O 4 (AO)
E-31 Not Used
E-32 Not Used
E-33 85B MAX-ER 2000 Power Relay (Current) 12 volts Nominal I/O 4 (DO)
E-34 85B 2-Speed Swing Selector - Ringer (Past) 12 volts Nominal
I/O 4 (DO)
E-35 80CA Front Drum Pawl Out Solenoid 12 volts Nominal
I/O 4 (DO)
E-36 81C Rear Drum Pawl In Solenoid 12 volts Nominal
I/O 4 (DO)
E-37 81CA Rear Drum Pawl Out Solenoid 12 volts Nominal
I/O 4 (DO)
Pin Wire Description
Test Voltage
(DC unless otherwise specified)
Board
(Signal Type)