Manitowoc Published 11-06-15, Control # 040-13 3-29
2250 SERVICE/MAINTENANCE MANUAL ELECTRIC SYSTEM
3
P12-34 DPF Regen Initiate 24 Volts Nominal
P12-39 DO-15 Grd CAN System Ground Ground
P12-40 DO-16 Grd CAN System Ground Ground
P2 Data Download/Upload Receptacle – Front Console Master Node
P2-1 Data TX1 RX1-35 Receive data from Crane Controller Variable 6 to 7 Volts Nominal
P2-2 Data RX1 TX1-34 Transmit data to Crane Controller Variable 6 to 7 Volts Nominal
P2-3 Data X Load Indicator Data Download N/A
P2-4 Logic Grd Ground Ground
Pin # Function Type Description
Test Voltage
(DC unless otherwise specified)