Manitowoc Published 11-06-15, Control # 040-13 3-55
2250 SERVICE/MAINTENANCE MANUAL ELECTRIC SYSTEM
12. Before starting the engine, power up programmable
controller (cab power switch ON and engine run/stop
switch in RUN) and set any operator programmable
control features (i.e. swing speed and torque, tagline
tension, etc.) if equipped.
13. Follow instructions in the Operator Manual to calibrate
pressure senders (transducers) and pump control
thresholds (feed forward).
14. Test all crane functions.
15. If you have any problems with the new software, contact
the Manitowoc Crane Care Lattice Team.
16. Return old EPROMs to your area Regional Service
Manager or the Manitowoc Crane Care Lattice Team.