Malfunctions in driving mode
8.5 Emergency operation and breakdown assistance
Operating manual 3 302 690 en 8 - 41
GMK4100L-1
23.11.2017
Check valves – switch off continuous
operation
Always switch off the continuous operation
for all valves (1).
(A) – Take the nut (2) off of the limit switch (4).
(B) – Fit the magnets (3) – pay attention
marking!
Tighten the nut (2) hand-tight on the valve (4).
Inserting the fuses
After emergency operation, you must insert the fuses again so that the 4th
axle line can be steered while driving.
Turn off the ignition.
Insert the fuse F2/5; à Fuses in the driver's cab, p. 8 - 50.
Insert the fuse F10; à Fuses in the battery box, p. 8 - 56.
After emergency
operation
Drive directly to the workshop and have the fault rectified.
The speed may be reduced depending on the extent of the error.