Starting/switching off the engine – for crane operation
10.2 Starting the engine – from the crane cab
10 - 8 3 302 690 en Operating manual
GMK4100L-1
23.11.2017
10.2.7 Checks after starting the engine
Check the display (1) on the CCS control unit
immediately after starting the engine.
When a symbol is displayed in the display
area (1);
à Malfunctions on the engine,
p. 8 - 19.
Also check the displays
1 Engine speed display
in rpm
2 AdBlue (DEF) filling level indicator
in per cent
3 Coolant temperature display
in °C (°F)
4 Fuel level display
in per cent
5 Voltage monitoring display
in volts
6 Hydraulic oil temperature display
in °C (°F)