Malfunctions during crane operation
14.6 Hydraulic emergency operation with the hand pump
Operating manual 3 302 690 en 14 - 55
GMK4100L-1
23.11.2017
14.6.4 Performing emergency activation
If the required hydraulic circuit has been
established, you can make the corresponding
crane movement using the hand pump (1).
Insert the pump lever (2) provided into the
holder at the hand pump lever.
Pump with the lever – the corresponding
crane movement is performed.
14.6.5 After emergency activation
You must restore the truck crane to its original state after finishing
emergency activation.
After each emergency activation
Switch valves 1 to 3 to crane operation; à p. 14 - 53.
Switch the valve 4 to crane operation; à p. 14 - 51.