Loading...
Crane operation
11.4 Operation of the rated capacity limiter
11 - 40 3 302 690 en Operating manual
GMK4100L-1
23.11.2017
Entering the
RCL code
You must enter the RCL code for the rigging mode according to the lifting
capacity table
.
Refer to the lifting capacity table for the
current rigging mode. The corresponding
RCL code (1) is specified at the bottom of
the table (e.g. 1100).
Select and confirm the symbol (2).
Select the necessary RCL code (3), for
example, 1100.
Confirm the selection.
The other displays will show the correspond-
ing rigging mode.
11.4.3 Pre-selecting telescoping
First enter the current rigging mode.
Select and confirm the symbol (1).
The
Pre-selection telescoping menu opens.
Enter the desired parameter (2); à p. 9 - 42.
The table shows all permissible telescop-
ings (4) and the associated parameter (3)
for the entered rigging mode and entered
parameter.
Select and confirm the line with the desired
telescope status, for example, line (5).
The
Enter rigging mode/telescope status menu
opens – the preselected telescope status (6)
is displayed.

Table of Contents