Crane operation
11.6 Settings and displays for crane operation
Operating manual 3 302 690 en 11 - 127
GMK4100L-1
23.11.2017
Economy steps
The economy steps 1 to 3:
The time interval between step 2 and step 3 is
60 seconds and cannot be adjusted.
Activate step 3 manually
• Press and hold the button (1) – for 3 seconds.
The engine for crane operation is switched off – APS is started.
Economy Mode display
Depending on which
Economy Mode is activated, the crane controller shows
the following background image
s
Step 1: The engine speed is reduced
Step 2: The superstructure drive is shut down
Step 3: The engine is switched off – APS
1)
is
started automatically