App - 19
Appendix 4 List of Functions Added by GT Designer2 Version Upgrade (For GOT1000 Series)
17
MAINTENANCE AND
INSPECTION
18
ERROR MESSAGE
AND SYSTEM
ALARM
APPENDICES
(Continued to next page)
Item Description
Version of GT
Designer2
Version of OS
GT
15
GT Soft
GOT1000
GT
11
SHINKO indicating
controller
connection
Supporting connection to SHINKO
indicating controller
2.43V
Communication driver
Shinko Technos Controller [03.01.**]
The functions to automatically stop
monitoring faulty stations and to
disconnect communications with
controllers are added
2.58L
Communication driver
Shinko Technos Controller [03.03.**]
CHINO controller
connection
Supporting connection to CHINO
controller
2.58L
Communication driver
CHINO Controllers(MODBUS)
[03.03.**]
The functions to automatically stop
monitoring faulty stations and to
disconnect communications with
controllers are added
FUJI SYS
temperature
controller
connection
Supporting connection to FUJI SYS
temperature controller
2.32J
Communication driver
FUJI PXR/PXG/PXH [03.00.**]
The functions to automatically stop
monitoring faulty stations and to
disconnect communications with
controllers are added
2.58L
Communication driver
FUJI PXR/PXG/PXH [03.03.**]
YAMATAKE
temperature
controller
connection
Supporting connection to YAMATAKE
temperature controller
2.18U
Communication driver
YAMATAKE SDC/DMC [02.02.**]
The functions to automatically stop
monitoring faulty stations and to
disconnect communications with
controllers are added
2.58L
Communication driver
YAMATAKE SDC/DMC [03.03.**]
YOKOGAWA
temperature
controller
connection
Supporting connection to YOKOGAWA
temperature controller
2.43V
Communication driver
YOKOGAWA GREEN/UT100/
UT2000 [03.01.**]
The functions to automatically stop
monitoring faulty stations and to
disconnect communications with
controllers are added
2.58L
Communication driver
YOKOGAWA GREEN/UT100/
UT2000 [03.03.**]
RKC temperature
controller
connection
Supporting connection to RKC
temperature controller
2.18U
Communication driver
RKC SR Mini HG(MODBUS)
[02.02.**]
Supporting connection to SRZ
2.58L
Communication driver
RKC SR Mini HG(MODBUS)
[03.03.**]
The functions to automatically stop
monitoring faulty stations and to
disconnect communications with
controllers are added
Inverter
connection
Supporting connection to inverter 2.18U
Communication driver
FREQROL 500/700 [02.02.**]
Setting range for Timeout Time has been
changed.
(3 to 30 seconds 1 to 30 seconds)
2.43V
Communication driver
FREQROL 500/700 [03.01.**]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT1000 GT11 and is the answer not in the manual?

Mitsubishi GOT1000 GT11 Specifications

General IconGeneral
Power Supply24V DC
Operating Temperature0 to 50°C
Storage Temperature-20 to 60°C
Screen Size5.7 inches
Resolution320 x 240 pixels
Communication InterfaceRS-422/485, USB
MemoryInternal flash memory
CPURISC
Touch PanelAnalog Resistive

Related product manuals