Maintenance & Troubleshooting 8 - 7
The MC92N0-G does
not accept scan input.
Scanning application
is not loaded.
Verify that the unit is loaded with a scanning application. See
DataWedge on page 4-5
or the System Administrator.
Unreadable bar
code.
Ensure the symbol is not defaced.
Distance between
exit window and bar
code is incorrect.
Ensure MC92N0-G is within proper scanning range.
MC92N0-G is not
programmed for the
bar code.
Ensure the MC92N0-G is programmed to accept the type of bar
code being scanned.
MC92N0-G is not
programmed to
generate a beep.
If a beep on a good decode is expected and a beep is not heard,
check that the application is set to generate a beep on good
decode.
Battery is low. If the scanner stops emitting a laser beam when the trigger is
pressed, check the battery level. When the battery is low, the
scanner shuts off before the MC92N0-G low battery condition
notification.
Note: If the scanner is still not reading symbols, contact the
distributor or Zebra.
WLAN connection is
lost when the
MC92N0-G is
connected to a host
computer using
ActiveSync. (Windows
devices only)
Microsoft security
feature prevents
connection to two
separate networks.
Disconnect from the WLAN network prior to connecting to a host
computer using ActiveSync.
MC92N0-G cannot find
any Bluetooth devices
nearby.
Too far from other
Bluetooth devices.
Move closer to the other Bluetooth device(s), within a range of 10
meters.
The Bluetooth
device(s) nearby are
not turned on.
Turn on the Bluetooth device(s) you wish to find.
The Bluetooth
device(s) are not in
discoverable mode.
Set the Bluetooth device(s) to discoverable mode. If needed, refer
to the device’s user documentation for help.
MC92N0-G keeps
powering down to
protect memory
contents.
The MC92N0-G’s
battery is low.
Recharge the battery.
Cannot extract
Real-time data.
(Windows devices
only)
MC92N0-G is not
responding.
Perform a warm boot then press F9 to extract data.
Table 8-1
Troubleshooting the MC92N0-G (Continued)
Problem Cause Solution

Table of Contents

Other manuals for Motorola MC92N0-G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motorola MC92N0-G and is the answer not in the manual?

Motorola MC92N0-G Specifications

General IconGeneral
BrandMotorola
ModelMC92N0-G
CategoryBarcode Reader
LanguageEnglish

Related product manuals