4-46 Features and Specifications
For Station Message Detail Recording (SMDR)
For Centralized Billing K-CCIS
Program/
Item No.
Description/Selection Assigned Data Comments
21-01-03
System Options for
Outgoing Calls – Trunk
Interdigit Time (External)
0~64800 seconds
Default is 5
The system waits for this time to expire before
placing the call.
35-01-04
SMDR Options – Omit
Digits
0 = Not Applied
1~24
Default is 0
The number of leading digits that do not print on
the SMDR report.
Program/
Item No.
Description/Selection Assigned Data Comments
35-01-06
SMDR Options – Minimum
Call Duration
0 = All
0~65535 seconds
Default is 0
A call must be longer than this duration to be
included in the SMDR report.
35-02-08
SMDR Output Options –
Incoming Call
0 = Not Displayed
1 = Displayed
Default is 1
Select whether or not incoming calls are displayed
on the SMDR report.
15-01-03
Basic Extension Data Setup
– SMDR Printout
0 = Not printed on SMDR
report
1 = Included on SMDR
Report
Default is 1
Use to include the extension being programmed in
the SMDR report.