Issue 2.0
5-22 SV9100 IP K-CCIS
2.2 VoIP IP Address Assignments
For this feature, the GPZ-IPLE, daughter board is installed on the GCD-CP10
blade. The GPZ-IPLE daughter board reduces the maximum capacity of trunks in
the system.
22-02-01
Incoming Call Trunk
Setup – Trunk Type
001 ~ 400
0 = Normal
1 = VRS (second dial tone if no
VRS installed)
2 = DISA
3 = DID
4 = DIL
5 = E&M Tie line
6 = Delayed VRS
7 = ANI/DNIS
8 = DID(DDI) Mode
Switching
Default is 0
Set the feature type for
the trunk you are
programming.
Table 5-8 VoIP IP Address Assignments
Program/
Item No.
Description/Selection Assigned Data Comments
84-26-01
IPL Basic Setup – IP
Address
XXX.XXX.XXX.XXX Assign the VOIPDB Gateway IP
Address.
Slot 1 = 172.16.0.20
84-26-02
IPL Basic Setup – RTP
Port Number
0~65534 Default:
RTP Port = 10020
84-26-03
IPL Basic Setup – RTCP
Port Number
(RTP Port Number + 1)
0~65534 Default:
RTCP = 10021
Table 5-7 Digital Trunk Assignments (Continued)